Evaperator
High-Performance. Every time.

rime’s Evaporator

Our Evaporators are efficient. They are designed with cutting-edge technology to deliver optimal cooling performance and engineered with durability in mind, ensuring reliable operation and precise temperature control in various applications.

Incorporating top-tier components from brands like Castel, Danfoss, GVN, and EMP papst Fans, rime Evaporators are the epitome of quality and longevity, making them the preferred choice for all your cooling needs.

Download our catalog for complete details and product selection.

View Models Download Catalog
ev1

Hinged outer tray for easy access and maintenance.

ev2

Outer tray thermally decoupled to prevent water condensation.

ev3

All the materials that have been utilized are food-safe

ev4

Easy access to all components for servicing and upkeep.

Build Qualities

evaperator

Robust
Construction

Our evaporators feature robust builds with galvanized steel for structural integrity and aluminum for lightweight efficiency, ensuring durability and corrosion resistance in diverse environments.

Precision
Engineering

Each unit is meticulously engineered with CNC-machined components to achieve precise tolerances, enhancing overall performance and reliability.

Efficient Heat
Transfer

Utilizing staggered copper tubes and high-performance aluminum fins, our evaporators maximize airflow and heat transfer efficiency, optimizing cooling effectiveness.

Reliable
Component

Equipped with EBM papst axial fans and AISI 321 stainless steel defrost heaters, our evaporators are designed for long-term reliability and consistent performance in refrigeration applications.


Technical Details

Technical Details
Refrigerant
• R404 • R507
Te (˚ C)
-10 -8 -25 -35
Tr (˚ C)
0 0 -18 -30
FS=4.5 mm
2.6-72 kw 2-57 kw
FS=7 mm
2.2-66.5 kw 1.6-50 kw 1.4-40 kw
FS=10 mm
1.8-64.7 kw 1.2-38 kw 0.8-23.5 kw

The evaporators operate within a temperature range of -40˚C to +5˚C, making them ideal for chiller, freezer, and blast freezer applications. Nominal capacities range from 1 to 70 kW when paired with low ozone depletion refrigerants like R404A and R507A.

Technical Details
Brand
ebm-papst
No. of Fans
Available

1 to 4
Diameter
300mm 400mm 500mm 630mm
Available Defrost Type
Electrical Coil Tray
Air Circulation

rime cubic draw-through evaporators come with EBM-Papst AC fans suitable for cold storage and freezing tunnels.

Technical Details
Heat Exchanger
Highly efficient with
optimized tube and
fin patterns
Fin Spacing 4.5mm |
7mm | 10mm
Available Material

Aluminum Copper Galvanized Steel
Components
Tube

Fin
Casing
Tray

Evaporators are available in three types of fin spacings: 4.5mm, 7mm, or 10mm, depending on their intended application. Standard models are equipped with electric defrost elements and can be customized to include air circulation upon request.

Evaporator Capacity
Fan
Heat Exchanger
EVAPORATOR NOMENCLATURE

Following Nomenclature Has Been Used For Defining Rime Evaporator

R C E 2 50
-
8
-
4
View Details
RCE130.4.4

RCE130.4.4

Practical Capacity (KW):2.9 @ SC2
RCE130.6.4

RCE130.6.4

Practical Capacity (KW):3.3 @ SC2
RCE230.4.4

RCE230.4.4

Practical Capacity (KW):5.9 @ SC2
RCE230.6.4

RCE230.6.4

Practical Capacity (KW):6.9 @ SC2
RCE330.4.4

RCE330.4.4

Practical Capacity (KW):8.6 @ SC2
RCE330.6.4

RCE330.6.4

Practical Capacity (KW):10.3 @ SC2
RCE140.4.4

RCE140.4.4

Practical Capacity (KW):5.8 @ SC2
RCE140.6.4

RCE140.6.4

Practical Capacity (KW):7.1 @ SC2
RCE240.4.4

RCE240.4.4

Practical Capacity (KW):11.6 @ SC2
RCE240.6.4

RCE240.6.4

Practical Capacity (KW):13.5 @ SC2
RCE340.4.4

RCE340.4.4

Practical Capacity (KW):17.4 @ SC2
RCE340.6.4

RCE340.6.4

Practical Capacity (KW):20.9 @ SC2
RCE150.4.4

RCE150.4.4

Practical Capacity (KW):11.0 @ SC2
RCE150.6.4

RCE150.6.4

Practical Capacity (KW):13.6 @ SC2
RCE150.8.4

RCE150.8.4

Practical Capacity (KW):15.1 @ SC2
RCE250.4.4

RCE250.4.4

Practical Capacity (KW):22.1 @ SC2
RCE250.6.4

RCE250.6.4

Practical Capacity (KW):26.9 @ SC2
RCE250.8.4

RCE250.8.4

Practical Capacity (KW):30.0 @ SC2
RCE350.4.4

RCE350.4.4

Practical Capacity (KW):33.4 @ SC2
RCE350.6.4

RCE350.6.4

Practical Capacity (KW):41.1 @ SC2
RCE350.8.4

RCE350.8.4

Practical Capacity (KW):45.2 @ SC2
RCE450.4.4

RCE450.4.4

Practical Capacity (KW):44.4 @ SC2
RCE450.6.4

RCE450.6.4

Practical Capacity (KW):54.3 @ SC2
RCE450.8.4

RCE450.8.4

Practical Capacity (KW):57.5 @ SC2
RCE263.4.4

RCE263.4.4

Practical Capacity (KW):36.9 @ SC2
RCE263.6.4

RCE263.6.4

Practical Capacity (KW):49.5 @ SC2
RCE263.8.4

RCE263.8.4

Practical Capacity (KW):56.2 @ SC2
RCE363.4.4

RCE363.4.4

Practical Capacity (KW):55.1 @ SC2
RCE363.6.4

RCE363.6.4

Practical Capacity (KW):73.9 @ SC2
RCE363.8.4

RCE363.8.4

Practical Capacity (KW):80.2 @ SC2
RCE130.4.7

RCE130.4.7

Practical Capacity (KW):2.4 @ SC2
RCE130.6.7

RCE130.6.7

Practical Capacity (KW):2.8 @ SC2
RCE230.4.7

RCE230.4.7

Practical Capacity (KW):4.8 @ SC2
RCE230.6.7

RCE230.6.7

Practical Capacity (KW):6.0 @ SC2
RCE330.4.7

RCE330.4.7

Practical Capacity (KW):7.3 @ SC2
RCE330.6.7

RCE330.6.7

Practical Capacity (KW):9.1 @ SC2
RCE140.4.7

RCE140.4.7

Practical Capacity (KW):4.7 @ SC2
RCE140.6.7

RCE140.6.7

Practical Capacity (KW):6.2 @ SC2
RCE240.4.7

RCE240.4.7

Practical Capacity (KW):9.4 @ SC2
RCE240.6.7

RCE240.6.7

Practical Capacity (KW):12.0 @ SC2
RCE340.4.7

RCE340.4.7

Practical Capacity (KW):14.4 @ SC2
RCE340.6.7

RCE340.6.7

Practical Capacity (KW):18.3 @ SC2
RCE150.4.7

RCE150.4.7

Practical Capacity (KW):8.9 @ SC2
RCE150.6.7

RCE150.6.7

Practical Capacity (KW):11.6 @ SC2
RCE150.8.7

RCE150.8.7

Practical Capacity (KW):13.3 @ SC2
RCE250.4.7

RCE250.4.7

Practical Capacity (KW):17.9 @ SC2
RCE250.6.7

RCE250.6.7

Practical Capacity (KW):23.4 @ SC2
RCE250.8.7

RCE250.8.7

Practical Capacity (KW):27.1 @ SC2
RCE350.4.7

RCE350.4.7

Practical Capacity (KW):27.3 @ SC2
RCE350.6.7

RCE350.6.7

Practical Capacity (KW):35.1 @ SC2
RCE350.8.7

RCE350.8.7

Practical Capacity (KW):40.8 @ SC2
RCE450.4.7

RCE450.4.7

Practical Capacity (KW):36 @ SC2
RCE450.6.7

RCE450.6.7

Practical Capacity (KW):47.2 @ SC2
RCE450.8.7

RCE450.8.7

Practical Capacity (KW):52.9 @ SC2
RCE263.4.7

RCE263.4.7

Practical Capacity (KW):30.1 @ SC2
RCE263.6.7

RCE263.6.7

Practical Capacity (KW):42.0 @ SC2
RCE263.8.7

RCE263.8.7

Practical Capacity (KW):49.3 @ SC2
RCE363.4.7

RCE363.4.7

Practical Capacity (KW):44.1 @ SC2
RCE363.6.7

RCE363.6.7

Practical Capacity (KW):63.2 @ SC2
RCE363.8.7

RCE363.8.7

Practical Capacity (KW):72.4 @ SC2
RCE130.4.10

RCE130.4.10

Practical Capacity (KW):1.7 @ SC3
RCE130.6.10

RCE130.6.10

Practical Capacity (KW):2.1 @ SC3
RCE230.4.10

RCE230.4.10

Practical Capacity (KW):3.5 @ SC3
RCE230.6.10

RCE230.6.10

Practical Capacity (KW):4.5 @ SC3
RCE330.4.10

RCE330.4.10

Practical Capacity (KW):5.1 @ SC3
RCE330.6.10

RCE330.6.10

Practical Capacity (KW):6.7 @ SC3
RCE140.4.10

RCE140.4.10

Practical Capacity (KW):3.4 @ SC3
RCE140.6.10

RCE140.6.10

Practical Capacity (KW):4.5 @ SC3
RCE240.4.10

RCE240.4.10

Practical Capacity (KW):6.7 @ SC3
RCE240.6.10

RCE240.6.10

Practical Capacity (KW):8.4 @ SC3
RCE340.4.10

RCE340.4.10

Practical Capacity (KW):10.2 @ SC3
RCE340.6.10

RCE340.6.10

Practical Capacity (KW):13.2 @ SC3
RCE150.4.10

RCE150.4.10

Practical Capacity (KW):6.4 @ SC3
RCE150.6.10

RCE150.6.10

Practical Capacity (KW):8.6 @ SC3
RCE150.8.10

RCE150.8.10

Practical Capacity (KW):10.2 @ SC3
RCE250.4.10

RCE250.4.10

Practical Capacity (KW):12.9 @ SC3
RCE250.6.10

RCE250.6.10

Practical Capacity (KW):16.7 @ SC3
RCE250.8.10

RCE250.8.10

Practical Capacity (KW):20.2 @ SC3
RCE350.4.10

RCE350.4.10

Practical Capacity (KW):19.4 @ SC3
RCE350.6.10

RCE350.6.10

Practical Capacity (KW):26.1 @ SC3
RCE350.8.10

RCE350.8.10

Practical Capacity (KW):30.5 @ SC3
RCE450.4.10

RCE450.4.10

Practical Capacity (KW):26.0 @ SC3
RCE450.6.10

RCE450.6.10

Practical Capacity (KW):33.7 @ SC3
RCE450.8.10

RCE450.8.10

Practical Capacity (KW):37.3 @ SC3
RCE263.4.10

RCE263.4.10

Practical Capacity (KW):21.1 @ SC3
RCE263.6.10

RCE263.6.10

Practical Capacity (KW):30.4 @ SC3
RCE263.8.10

RCE263.8.10

Practical Capacity (KW):37.0 @ SC3
RCE263.10.10

RCE263.10.10

Practical Capacity (KW):41.0 @ SC3
RCE363.4.10

RCE363.4.10

Practical Capacity (KW):31.9 @ SC3
RCE363.6.10

RCE363.6.10

Practical Capacity (KW):44.9 @ SC3
RCE363.8.10

RCE363.8.10

Practical Capacity (KW):50.7 @ SC3
RCE363.10.10

RCE363.10.10

Practical Capacity (KW):52.7 @ SC3

Contact Us

rime Group FZE

Plot No. MO0535 North Zone JAFZA,

Dubai, United Arab Emirates

P.O. Box 26820

+971 4 4918522

sales@rimegroup.com